Ellie reconciles a portfolio energy and carbon register against every utility bill and finds the consumption it understates.

Full description

Treverton's Singapore portfolio energy tracker says consumption fell 4.8%. Ellie checks it against 60 electricity bills, the meter-exchange record and the reporting policy: five tracker cells understate by 9,040 MWh, so consumption is 127,680 MWh, up 2.5%, and Scope 2 emissions are 51,327 t, with 94.5% of floor area on actual data. The March board paper needs correcting.

Key points

  • Every bill reconciled to the register
  • A meter exchange that the tracker double-subtracted
  • Scope 2 restated before disclosure
Transcript

Treverton is an energy and carbon reporting demo for five Singapore buildings going to the sustainability committee on the 8th of October. The property manager tracker says electricity fell 4.8% this year on fully actual data. The data room holds the monthly electricity bills, the meter records, the tracker, the asset register, the sustainability policy, and the last board paper. The asset team starts with Kerridge's tracker as it stands, portfolio total, year-on-year, and what it claims on data quality.

It reports a fall of 4.8% with every month marked actual. At Tuas South, a meter was exchanged in March and the tracker booked minus 4,120 megawatt hours. The exchange record itself says not to subtract 1 meters reading from the others and the March bill shows 2,330. Rebuilt from the bills, the year did not fall 4.8%. It rose two and a half. At Serangoon, two missing months were keyed as zero and labeled actual, which the policy forbids, so Ellie estimates them from last year.

At Brentmoor, every other month is an estimated reading with no site visit recorded. The workbook sets its basis. The bills are the source and the tracker is the record under test. The register holds every building and month, each row citing its bill and page. The reconciliation tests every month against the tracker and names each cell that is wrong. And the exception log gives every error its evidence, starting with the negative month at Tuas South.

On the dashboard, scope 2 emissions are 51,327 tons, not 47,693. In the flags, Orchard's July and August were copies of June, though both bills were in the folder. The check then becomes a skill with an agent on the folder that rebuilds the register every time new bills land. Each run flags any gap before it reaches the committee. The brief for the committee carries the corrected position. Click a figure and the bill behind it opens alongside. It asks the committee to correct the March board paper as well.

This is what a general model is likely to miss. The tracker looks complete. Every month filled, every month marked actual. The errors only show when each figure is read against its own bill. the meter exchange record and the policy's rules on missing and estimated months. Three errors account for all 9,040 megawatt hours.